Measuring AC and DC Currents
LeCroy current probes do not require the breaking of a circuit or the insertion
of a shunt to make accurate and reliable current measurements. Based on a
combination of Hall effect and transformer technology, LeCroy current probes
are ideal for making accurate AC, DC, and impulse current measurements.
Fully Integrated with Oscilloscope
Many current probes require external power supplies or amplifiers to display a
waveform on the oscilloscope screen. All LeCroy current probes are powered
through the LeCroy ProBus® connection and require no additional hardware. Along
with providing power, the ProBus connection allows the current probe and
oscilloscope to communicate, resulting in current waveforms automatically
displayed on screen in Amps, and calculated power traces scaled correctly in
Watts. This full integration also allows for Degauss and Autozero functions to
be done directly from the oscilloscope with a single button press.
Applications
LeCroy current probes are available in a wide range of models for a wide range
of applications. The full range of LeCroy current probes includes models with
bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 10
mA/div. Multiple current probes can be used together to make measurements on
three-phase systems, or a single current probe can be used with a voltage probe
to make accurate instantaneous power measurements. LeCroy current probes are
often used in applications such as the design and test of switching power
supplies, motor drives, electric vehicles, and uninterruptible power supplies
Model
|
Max Continuous Input Current
|
Max Peak
Current
|
Bandwidth
|
Minimum Sensitivity
|
Coupling
|
Max Conductor Size (diameter)
|
Interface
|
CP030
|
30A
|
50A <10µs
|
50 MHZ
|
20mA/div
|
AC, DC, GND
|
5mm
|
Probus, 1MΩ only
|
CP031
|
30A
|
50A <10µs
|
100 MHZ
|
20mA/div
|
AC, DC, GND
|
5mm
|
Probus, 1MΩ only
|
AP015
|
30A
|
± 50 A < 10 s.
|
50 MHz
|
10 mA/div
|
AC, DC, GND
|
5 mm
|
Probus, 1MΩ only
|
CP150
|
150 A
|
500 A <30 µs
|
10 MHz
|
200 mA/div
|
AC, DC, GND
|
20 mm
|
Probus, 1MΩ only
|
CP500
|
500 A
|
700 A
|
2 MHz
|
200 mA/div
|
AC, DC, GND
|
20 mm
|
Probus, 1MΩ only
|
|
 |
CP030
Description:
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse

View Datasheet |
 |
| Electrical Characteristics | | Risetime (typical): | < 7ns |  | | Coupling: | AC, DC, GND |  | | Minimum Sensitivity: | 20 mA/div |  | | Max Continuous Input Current: | 30 A |  | | Max Peak Current (at pw): | 50 A <10 µs |  | | General Characteristics | | Max Conductor Size (diameter): | 5mm |  | | Interface: | Probus, 1 MΩ only |  | | Cable Length: | 2m |  | | Max Altitude: | 2000m |  | | Weight: | 240 g |  | | Max Relative Humidity: | 80% |  | | Usage Environment: | Indoor |  | | Operating Temperature: | 0 C to 40 C |  | | Main Specifications | | Bandwidth: | 50 MHz |  |
|  | |  |
 |
CP031
Description:
30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse

View Datasheet |
 |
| Electrical Characteristics | | Risetime (typical): | < 3.5ns |  | | Coupling: | AC, DC, GND |  | | Minimum Sensitivity: | 20 mA/div |  | | Max Continuous Input Current: | 30 A |  | | Max Peak Current (at pw): | 50A <10 µs |  | | General Characteristics | | Max Conductor Size (diameter): | 5 mm |  | | Interface: | Probus, 1MΩ only |  | | Cable Length: | 2m |  | | Max Altitude: | 2000m |  | | Weight: | 240 g |  | | Max Relative Humidity: | 80% |  | | Usage Environment: | Indoor |  | | Operating Temperature: | 0 C to 40 C |  | | Main Specifications | | Bandwidth: | 100 MHZ |  |
|  | |  |
 |
AP015
Description:
AP015, 30 Amps, 50MHz BW Current Probe - AC/DC, 50 Amp Peak Pulse

View Datasheet |
 |
| Electrical Characteristics | | Risetime (typical): | < 7 ns |  | | Coupling: | AC, DC, GND |  | | Minimum Sensitivity: | 10 mA/div |  | | Max Continuous Input Current: | 30 A |  | | Max Peak Current (at pw): | 50 A < 10 s. |  | | General Characteristics | | Max Conductor Size (diameter): | 5 mm |  | | Interface: | ProBus, 1MΩ only |  | | Cable Length: | 2 m |  | | Max Altitude: | 2000 m |  | | Weight: | 300 g |  | | Max Relative Humidity: | 80% (maximum 31 C) |  | | Usage Environment: | Indoor |  | | Operating Temperature: | 0 C to 40 C |  | | Main Specifications | | Bandwidth: | 50 MHz |  |
|  | |  |
 |
CP150
Description:
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse

View Datasheet |
 |
| Electrical Characteristics | | Risetime (typical): | <35 ns |  | | Coupling: | AC, DC, GND |  | | Minimum Sensitivity: | 200 mA/div |  | | Max Continuous Input Current: | 150 A |  | | Max Peak Current (at pw): | 500 A <30 µs |  | | General Characteristics | | Max Conductor Size (diameter): | 20 mm |  | | Interface: | ProBus, 1 MΩ only |  | | Cable Length: | 2 m |  | | Max Altitude: | 2000 m |  | | Weight: | 500 g |  | | Max Relative Humidity: | 80% |  | | Usage Environment: | Indoor |  | | Operating Temperature: | 0 C to 40 C |  | | Main Specifications | | Bandwidth: | 10 MHz |  |
|  | |  |
 |
CP500
Description:
500 Amps, 2 MHz BW Current Probe - AC/DC , 700 Amp Peak

View Datasheet |
 |
| Electrical Characteristics | | Risetime (typical): | <175 ns |  | | Coupling: | AC, DC, GND |  | | Minimum Sensitivity: | 200 mA/div |  | | Max Continuous Input Current: | 500 A |  | | Max Peak Current (at pw): | 700 A |  | | General Characteristics | | Max Conductor Size (diameter): | 20 mm |  | | Interface: | ProBus, 1 MΩ only |  | | Cable Length: | 6 m |  | | Max Altitude: | 2000 m |  | | Weight: | 630 g |  | | Max Relative Humidity: | 80% |  | | Usage Environment: | Indoor |  | | Operating Temperature: | 0 C to 40 C |  | | Main Specifications | | Bandwidth: | 2 MHz |  |
|  | |  |
 |
DCS015
Description:
Deskew Calibration Source for AP015

|
 |
| The DCS015 calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the CP031, CP030 and AP015 are compatible with the DCS015. |
|  | |  |
|
|