WaveExpert Series Oscilloscope

WaveExpert Series

In recent years, the rates of serial data signals have increased steadily from 2.5 Gb/s to 40 Gb/s and beyond. All this speed, of course, pushes up the bandwidth requirements of oscilloscopes. However simply providing this bandwidth is not sufficient for qualifying these high-speed links. High bandwidth oscilloscopes must have the detailed analysis capability required by next-generation standards. Adding to the measurement complexity is the emergence of receiver equalization which allows high-speed serial data links to operate error-free even when the signal is severely distorted. The WaveExpert 100H is the ideal signal integrity analysis solution for these applications.



Ultra-High Bandwidth Signal Analysis

Eye pattern analysis is the primary method of signal integrity testing for optical signals and the WaveExpert performs this analysis over 20 times faster than conventional sampling oscilloscopes.

A maximum bandwidth of 100 GHz along with a 230 fsrms noise floor enables measurements on the fastest optical signals.

View more information on Optical Measurements >

Highly Accurate Jitter Analysis

The low jitter noise floor of the HCIS timebase along with LeCroy’s innovative Q-Scale jitter analysis provides over 3 times the accuracy over conventional sampling scope methods for all jitter types.

View more information on Jitter Analysis >

 

Up to 20 GHz TDR with Full S-paramter Measurements

The standard TDR analysis package included with the WaveExpert 100H offers full reference plane calibration and 1 and 2 port differential S-parameter measurement fully integrated into the instrument interface.

View more information on TDR >

 

Eye Doctor™ Offers Virtual Probing and Equalized Signals

The Virtual Probing and equalized receiver emulation features in the Eye Doctor package provide full end-to-end signal integrity analysis of serial data systems employing equalization.

View more information on Eye Doctor >

Timebase
Parameter Sequential High Stability w/ CIS (WE-CIS and WE-HCIS)
Sample Rate 1 MS/s 10 MS/s
Frequency Range DC to 5 GHz, using Trigger input 5 GHz-14 GHz, using CLK/Prescale input up to 40 GHz, using SDA-TPS accessory 62.5 MHz-125 MHz, using Trigger input 125 MHz-14 GHz, using CLK/Prescale input up to 40 GHz, using SDA-TPS accessory
Pattern Lock N/A YES, up to PRBS 23
Minimum Time Per Division 1 ps 1 ps
Time Resolution 100 fs rms 100 fs rms
Timebase Range 1 ps/div to 1 ms/div 1 ps/div to 500 ns/div (4 M memory)
Timebase Delay Time Range 25 ns-10 ms ±1 pattern
Time Interval Accuracy ±1 ps ±0.1% of reading Determined by trigger signal
Long Term Stability ±5 ppm Determined by trigger signal
Maximum Record Length
  Standard
  Optional
 
100k samples
N/A
 
64M samples 1 Ch, 16M samples 4 Ch
510M / 1 Ch, 256M / 2 Ch, 128M / 4 Ch
Jitter 1 ps typical, 1.2 ps guaranteed HCIS: 230 fs rms typical, 250 fs rms guaranteed
CIS: 500 fs rms typical, 600 fs rms guaranteed (3 Gb/s-40Gb/s)
Trigger and Clock Inputs
Parameter Trigger Input CLK/Prescale Input
Connector Type 2.92 mm 2.92 mm
Impedance 50 Ω nominal 50 Ω nominal
Input Amplitude ±1 V 0.0 dBm ±6 dBm
Max. Input Voltage ±2.5 V ±2.5 V
Coupling DC AC coupled
Trigger Sensitivity -10 dBm at 100 MHz, -5 dBm at 5 GHz -5 dBm at 14 GHz
Trigger Gating (Sequential mode only) Enable: 2.0–3.5 V
Disable:0–0.8 V
 
Trigger Gating Delay (Sequential mode only) Disable: 24 ns+ trigger period + time window setting
Enable: 32 ns
 
Electrical Sampling Modules
  20 GHz 30 GHz 50 GHz 70 GHz 100 GHz
Connector Type 2.92 mm 2.92 mm 2.4 mm 1.85 mm 1 mm
Rise Time 18 ps 12 ps 8 ps 5 ps 4 ps
Bandwidth 20 GHz 30 GHz 50 GHz 70 GHz 100 GHz
Input Voltage Range  2 Vpk-pk
DC Vertical Voltage Accuracy (worst case) <1% (800 mVp-p signal)
Aberrations First 40ps:±10%, 40 ps to 200 ps:±5%, 200 ps - 10 ns ±2%
Rms Noise 700 µV max. (500 µV typical) 1 mV (typical) 2 mV (typical) 3 mV (typical) 3 mV (typical)
Offset Range

±1 V

Optical Sampling Modules 
SO-50 (50 GHz)  
Optical Bandwidth  50 GHz (nominal)
Connector diameter  9 µm
FWHM (50%)  8.8 ps (max.), 8.5 ps (typical)
Wavelength Range  1280 to 1620 nm
Responsivity  17 V/W (typical) 15 V/W (min.)
@ 1564 nm, 11 V/W (typical)
9 V/W (min.) @ 1310 nm
Maximum Peak Optical Input  50 mW (+17 dBm)
Maximum Average Optical Input  20 mW (+13 dBm)
Noise Equivalent Power  83 µW (-11 dBm)
@ 50 GHz bandwidth with
150 MHz IF bandwidth
Optical Power Monitor  -30 dBm to +10 dBm ±5%
Optical Return Loss  > 25 dB @ 1550 nm
Sensitivity (Unfiltered)  0 dBm
SO-25 (28 GHz)  
Optical Bandwidth  28 GHz
Connector diameter  9 µm
FWHM (50%) 15.5 ps (max.) 15 ps (typical)
Wavelength Range  1280 to 1620 nm
Responsivity  17 V/W (typical) 15 V/W (min.)
@ 1564 nm, 11 V/W (typical)
9 V/W (min.) @ 1310 nm
Maximum Peak Optical Input  50 mW (+17 dBm)
Maximum Average Optical Input  20 mW (+13 dBm)
Noise Equivalent Power  47 µW (-13.2 dBm)
@ 28 GHz bandwidth with
150 MHz IF bandwidth
Optical Power Monitor  -30 dBm to +10 dBm ±5%
Optical Return Loss  > 25 dB @ 1550 nm
Sensitivity (Unfiltered)  -2.5 dBm
SO-10 (10 GHz)  
Optical Bandwidth  10 GHz
Connector diameter  62.5 µm/50 FC
FWHM (50%)  51 ps (max.) 48 ps (typical)
Wavelength Range  750 to 1650 nm
Responsivity 450 V/W (typical) 425 V/W (min.)
@ 1310 nm, 425 V/W (typical)
400 V/W (min.) @ 1565 nm,
225 V/W (typical) 200 V/W (min.)
@ 850 nm
Maximum Peak Optical Input  5 mW
Noise Equivalent Power (Unfiltered)  3 µW (max.) 2 µW (typical) @ 10 GHz optical bandwidth into 150 MHz IF bandwidth
Optical Power Monitor  -30 dBm to 10 dBm, ±5%
Optical Return Loss  -22 dB (SM), -14 dB (MM)
Noise Equivalent Power  2.5 W rms 1550 SM and
1310 MM, 2.1 W rms 1310
SM, 3.7 W 850 MM
Sensitivity (Unfiltered)  -15 dBm 10.7 Gb/s 1550 SM,
-14 dBm 12.5 Gb/s 1550 SM
  
Optical Reference Receiver Filters for SO 10 Module 
Individual Filters  
155 Mb/s  REF-00155
622 Mb/s  REF-00622
1.063 Gb/s  REF-01063
1.250 Gb/s  REF-01250
2.125 Gb/s  REF-02125
2.48832 Gb/s  REF-02488
2.5 Gb/s  REF-02500
3.125 Gb/s  REF-03125
3.188 Gb/s  REF-03188
3.320 Gb/s  REF-03320
4.250 Gb/s  REF-04250
9.953 Gb/s  REF-09950
10.31 Gb/s  REF-10310
10.52 Gb/s  REF-10520
10.66 Gb/s  REF-10660
10.71 Gb/s  REF-10710
11.1 Gb/s  REF-11100
   
Filter Kits  
REFKIT-TELCO ? SONET/SDH Kit. Includes: REF-00155, REF-00622,
REF-2488, REF-09950, REF-10660, REF-10710, REF-03320
REFKIT-SBUS ? Serial Bus Kit. Includes: REF-01063, REF-01250,
REF-02125, REF-02500, REF-03125, REF-03188, REF-04250, REF-09950,
REF-10310, REF-11100
 
TDR Step Generator
TDR Step Generator (ST-20)
Step Rise Time 20 ps
TDR Step Voltage 250 mV
Resistance 50 Ω
TDR Pulse Rate 1 MHz
Offset Range ±1 V
Step Flatness First 40 ps: ±10%, 40 ps–200 ps: ±5%, 200 ps–10 ns ±2%
Pulse Width 300 ns ±15 ns
Clock Recovery and Source Optical/Electrical Modules
Clock Recovery Modules
CDR-E135  
Frequency Range  All standard data rates from 622 Mb/s?8 Gb/s, up to 13.5 Gb/s with option 001
Input Sensitivity  100 mV up to 7 Gb/s, 200 mV from 7 Gb/s?13.5 Gb/s
Max. Input Level  2 Vp-p
Clock Out Voltage   500 mVp-p minimum
Data Output Jitter  0.005 UI rms @ 10Gb/s (500 fs rms typical)
Input Return Loss 15 dB from 622 MHz–10 GHz, 10 dB from 10 GHz–25 GHz
Output Clock Rise/Fall Time   30 ps (20%–80%)
PLL Loop Bandwidth  6 MHz
CDR-O125  
Configuration  Includes one Multi-mode splitter and one Single-mode splitter for both serial data and optical applications
Frequency Range  12.5 MHz–2.7 GHz, 9.9 GHz–12.5 GHz
Wavelength Range  750 nm to 1650 nm
Clock and Clock/8 Output Voltage  300 mVp-p (typical)
Data Output Jitter  0.01 UI rms (12.5 MHz–12.5 GHz)
Optical Sensitivity for Clock Recovery (Not including loss from external optical splitter) -19 dBm, typical @ 1564 nm
-17 dBm, minimum @ 1564 nm
-19 dBm, typical @ 1310 nm
-17 dBm, minimum @ 1310 nm
-17 dBm, typical @ 850 nm
-14 dBm, minimum @ 850 nm
   
Pulse Pattern Generator
PPG-E135  
Frequency Range  2.45 to 2.875 GHz
4.9 to 5.75 GHz
9.8 to 11.5 GHz
Data Patterns  2N-1, N=7, 10, 15, 23, 31
Mark Density  0.5, 0.25, 0.125
0.875 or 0.750 posssible with Data Invert
Data Output Voltage  500 mVp-p, 1000 mV differential
Data Output Jitter  < 1 ps rms
Data Output Rise/Fall Time  30 ps (20–80%)
Clock Out Level  > 0 dBm ±3 dBm
External Clock Input Power  > 0 dBm
External Clock Input Frequency >50 MHz–12.5 GHz
Frequency Accuracy >±3 ppm
Front Panel Connectors
Data+, Data-
CLK Input, CLK Output
2.92 mm (3.5 mm compatible) SMA
Power Requirements
100-200 Vrms (±10%) at 50/60 Hz; 115 Vrms (±10%) at 400 Hz, Automatic AC Voltage Selection Installation Category: 300V CAT II; Max Power Consumption: 400 VA (400 W)
 
Environmental
Temperature (Operating) +5 C to +40 C including CD-ROM drives
Temperature (Non-Operating) -20 C to +60 C
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +30 C.
Upper limit derates to 25% relative humidity (non-condensing) at +40 C
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +25 C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 20 gpeak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
   
Physical Dimensions
Dimensions (HWD)
(height excludes feet)
264 mm x 397 mm x 491 mm;
10.4" x 15.6" x 19.3"
Weight 40 lb; 18 kg
Shipping Weight 52 lb; 24 kg
 
Certifications
CE Compliant, UL and cUL listed; Conforms to EN 61326; EN 61010-1;
UL 61010-1; and CSA C22.2 No. 61010-1
Memory Options
WE-XXL510M (1 Ch), 255M (2 Ch), 128M (4 Ch) Waveform Memory
WE9K-L100K samples/channel memory
General Purpose Software
EYEDREye Doctor (Virtual Probe and Equalizer emulation) bundle
EYEDR-EQEye Doctor Equalized receiver emulation
EYEDR-VPEye Doctor Virtual Probing element
WE-CISCIS time base (500 fs RMS jitter) (cannot be ordered with WE-HCIS)
WE-HCISHigh stability CIS time base 230 fs RMS jitter (cannot be ordered with WE-CIS)
WE-SDAJitter Analysis Software PackageTj, Rj, Dj, DDj, DCD, ISI (requires WE-CIS or WE-HCIS)
WE9K-XDEVAdvanced Customization Sortware
WE9K-XWEBProcessing Web Editor Software Package for functions and parameters
Digital Filtering Software
WE9K-DFP2Digital Filter Software
Timebase Options
SDA100G-HCISHigh Stability CIS Timebase
Storage Devices
WE9K-RHDRemovable Hard Drive Package
WE9K-RHD-2Additional Removable Hard Drive
Remote Control/Network Options
GPIB-1IEEE-488 GPIB Remote Control Interface
Trigger Extension Accessories
SDA-TPSTrigger Prescaler
WE9K-GTGated Trigger
Miscellaneous Accessories
ADAPT-1001 mm F-F Adapter
ADAPT-100-1851 mm to 1.85 mm F-F Adapter
ADAPT-1851.85 mm F-F Adapter
ADAPT-2922.92 mm F-F Adapter
ADAPT-292-SMA2.92 to SMA F-F Adapter
DMD-1Dual Monitor Display
KYBD-1Keyboard
TW-44 in-lb Torque Wrench
TW-88 in-lb Torque Wrench
WE-CMBlank Cover Module for WaveExpert series oscilloscopes
Rackmounts, Carts and Cases
OC1021OC1021 scope cart is sturdy and mobile
OC1024OC1024 scope cart is sturdy and mobile
RMA-25Rackmount Kit - 25 inch Slide
RMA-30Rackmount Kit - 30 inch Slide
Electrical Sampling Heads
SE-100100 GHz electrical sampling head
SE-3030 GHz electrical sampling head
SE-5050 GHz electrical sampling head
SE-7070 GHz electrical sampling head
ST-2020 GHz electrical sampling head with TDR
Probe Adapters
CALKIT-OSL3.5 mm Coaxial Calibration Kit (includes Open, Short, and 50 ohm reference standards)
ME-151.5 meter Module Extender Cable
Product Resources
Downloads
Additional Resources