WaveSurfer Xs Series Oscilloscope

WaveSurfer 104MXs, WaveSurfer 24MXs, WaveSurfer 44MXs, WaveSurfer 64MXs, WaveSurfer 104Xs, WaveSurfer 64Xs, WaveSurfer 62Xs, WaveSurfer 44Xs, WaveSurfer 42Xs, WaveSurfer 24Xs

Quick Specs
  • - 200 MHz to 1 GHz Bandwidth
  • - 2.5 GS/s (up to 5 GS/s for 1 GHz)
  • - Big 10.4" LCD Display
  • - Small 6" footprint
Configure System
<
 

WaveSurfer
24Xs

WaveSurfer
44Xs

WaveSurfer
42Xs

WaveSurfer
64Xs

WaveSurfer
62Xs

WaveSurfer
104Xs

WaveSurfer
104MXs

Bandwidth (@ 50Ω)

200 MHz

400 MHz

600 MHz

1 GHz

Rise Time

1.75 ns

875 ps

625 ps

400 ps

Input Channels

4

2

4

2

4

Display

10.4" Color flat-panel TFT-LCD, 800 x 600 SVGA, touch screen

Sample Rate (single-shot)

2.5 GS/s (all channels)

2.5 GS/s (5 GS/s interleaved)

5 GS/s (all Channels)

Sample Rate (RIS mode)

50 GS/s

Standard Record Length

2.5 Mpts/Ch (all channels)

10 Mpts/ch (all channels)

Standard Capture Time

up to 1 ms at full sample rate

Vertical Resolution

8 bits

Vertical Sensitivity (V/div)

2 mV/div–10 V/div (1 MΩ); 2 mV/div–1 V/div (50 Ω)

Vertical (DC Gain) Accuracy

±1.0% of full scale (typical); ±1.5% of full scale ≥ 10 mV/div (warranted)

Vertical Offset Range

±1 V (2–50 mV/div), ±10V (100 mV–1 V/div), ±100 V (2–10 V/div)

BW Limit

20 MHz

20 MHz, 200 MHz

Maximum Input Voltage

CAT I: 400 V max. (DC + Peak AC ≤ 5 kHz) with 1 MΩ input. 5 Vrms with 50 Ω input

50 Ω:5 VRms 1 MΩ: 250 V max (Peak AC: ≤ 10 KHz + DC)

Input Coupling

AC, DC, GND (DC and GND for 50 Ω)

Input Impedance

1 MΩ || 16 pF, or 50 Ω ±1%,

1 MΩ || 20 pF, or 50 Ω

Probing System

BNC or ProBus

Probes

One PP009 (5 mm) per channel standard

One PP0011 (5 mm) per channel (standard)

Time Base Range

200 ps/div–1000 s/div

Time Base Accuracy

10 ppm

Trigger Modes

Normal, Auto, Single, and Stop

Trigger Sources

Any input channel, External, Ext/10, or line; slope and level unique to each source (except for line trigger)

Trigger Coupling

DC, AC, HFRej, LFRej

Pre-trigger Delay

0–100% of full scale

Post-trigger Delay

0–10,000 divisions

Trigger Hold-off

1 ns to 20 s or 1 to 1,000,000,000 events

Internal Trigger Level Range

±4.1 div from center

External Trigger Range

EXT/10 ±4V; EXT ±400 mV

Standard Triggers

Edge

Triggers when signal meets slope (positive, negative, or Window) and level condition

Glitch

 

Triggers on positive or negative glitches with widths selectable from 500 ps to 20 s or on intermittent

faults. Includes exclusion mode (trigger on intermittent faults by specifying the nominal width period).

Width

 

Triggers on positive or negative pulse widths selectable from 500 ps to 20 s or on intermittent faults.

Includes exclusion mode (trigger on intermittent faults by specifying the nominal width period).

Logic (Pattern)

 

Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input).

Each source can be high, low, or don’t care. The High and Low level can be selected independently.

TV-Composite Video

 

Triggers selectable fields (1, 2, 4, or 8), Positive or Negative slope, for NTSC, PAL, SECAM,

or non-standard video (up to 1500 lines)

Optional SMART Triggers™ (WSXs-ADVTRIG option - *Standard on WS 104 MXs)

Runt

Triggers on positive or negative runts defined by two voltage limits and two time limits.

Select between 1 ns and 20 s. Includes exclusion mode (trigger on intermittent faults by

specifying the nominal width or period).

Slew Rate

Triggers on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 s.

Includes exclusion mode (trigger on intermittent faults by specifying the nominal width period).

Interval (Signal or Pattern)

Triggers on intervals selectable between 1 ns and 20 s.

Dropout

 

Triggers if signal drops out for longer than selected time between 1 ns and 20 s.

Includes exclusion mode (trigger on intermittent faults by specifying the nominal width or period).

Qualified (State or Edge)

Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is 1 ns to 20 s, or 1 to 1,000,000,000 events. Includes exclusion mode (trigger on intermittent faults by specifying the nominal width or period).

HDTV Trigger
Optional, Standard on WS 104MXs

Trigger on 1080i, 1080p and 720p formats along with non-standard formats up to 2000 lines.

Measure, Zoom, and Math Tools

Standard Parameter Measurements

Up to 6 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base (Low), Cyclic Area, Cyclic Mean, Cyclic RMS, Cyclic Std. Deviation, Delay, Duty, Fall Time (90%-10%), Fall Time (80%-20%), Frequency, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Period, Peak-Peak, Phase, Rise Time (10%-90%), Rise Time (20%-80%), RMS, Skew, Standard Deviation, Top (High), Width+, Width-. Measurements may be gated.

Zooming

Use front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area.

Standard Math

 

Operators include Sum, Difference, Product, Ratio, and FFT (up to 25 kpts with power spectrum output and rectangular, VonHann, and FlatTop windows). 1 math function may be defined at a time.

Extended Math (WSXs-MATHSURF Option - *Standard on WS 104 MXs)

Adds the following additional math functions: Absolute Value, Averaging (summed and continuous), Derivative, Envelope, Enhanced Resolution (to 11 bits), Floor, Integral, Invert, Reciprocal, Roof, Square, and Square Root. Also adds chaining of two math functions and rescaling to different units.

WaveStream™ Fast Viewing Mode

Intensity

256 Intensity Levels, 1-100% adjustable via front panel control

Number of Channels

up to 4 simultaneously

Max. Sampling Rate

2.5 GS/s

Waveforms/second (continuous)

up to 8000 waveforms/second

Operation

Front panel toggle between normal Real-Time mode and LeCroy WaveStream Fast Viewing mode

Analog Persistence

Type

Analog or color-graded.

Saturation

Variable saturation level, adjustable from front panel

Aging Time

Adjustable from 500 ms to infinity

Operation

Software user interface ON/OFF and type selectability. When ON, persistence applied to all waveforms.

Automatic Setup

Auto Setup

 

Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals.

Vertical Find Scale automatically sets the vertical sensitivity and offset for the selected channel

Setup and Waveform Storage

Front Panel and Instrument Status

Save to the internal hard drive, over the network, or to a USB connected peripheral device.

Waveform Traces

Save to one of four internal memories with 16 bit resolution for recall/comparison.

Waveform Data

Save to the internal hard drive, over the network, or to a USB connected peripheral device.

Documentation and Connectivity

Printing

 

Connect to any Windows® XP-compatible printer using any of the available USB 2.0 ports. Load any

standard Windows XP printer driver onto the unit as future needs require.

E-mail

 

Configure the unit to send an e-mail of a screen image in a variety of formats using MAPI

(i.e., through a default e-mail program) or SMTP (no additional program needed).

Waveform Memories

Save waveform data as a reference trace to be compared to channels, zooms, or math functions.

Waveform File Data

Save waveform data in the following formats: Binary, ASCII, Excel, Mathcad, MATLAB.

Screen Image

 

 

Save a screen image to the internal hard drive, a user-supplied USB memory stick, or any other

peripheral connected to one of the five USB 2.0 ports. Image can be saved in a variety of formats,

and with white or black background.

Waveform Labeling (Annotation)

Attach up to 10 labels to any combination of waveforms. Labels appear on screen images.

Hardcopy Front Panel Button

 

Configure the front panel Hardcopy button to send an e-mail, save a screen image, save waveform

file data, and save to the clipboard.

Networking

 

Standard 10/100Base-T Ethernet interface (RJ-45 connector). Connect to any network using DHCP

with automatically assigned IP address.

Remote Control

Via Windows automation, or via LeCroy Remote Command Set (via Ethernet or GPIB)

USB Ports

5 USB ports (one on front of instrument) support Windows compatible devices

External Monitor Port Standard

15-pin D-Type female SVGA-compatible connector for external color display

Parallel Port

Not supplied

Serial Port

9-pin D-type male (not for remote oscilloscope control)

Audio Port

Mic Input, Line Input, Line Output

GPIB Port (Accessory)

Supports IEEE – 488.2 (using NI USB-GPIB-B)

Outputs

Calibrator

1 kHz square wave, +1.0 V into 1 M&Omega, output on front panel test point and ground lug

Control Signals

 

Rear Panel: TTL level, BNC output; Choice of trigger ready, trigger out, pass/fail status.

(output resistance 300 Ω typical)

Environmental and Safety

Temperature (Operating)

+5 °C to +40 °C

Temperature (Non-Operating)

–20 °C to +60 °C

Humidity (Operating)

 

5% to 80% relative humidity (non-condensing) at ≤ 30 °C.

Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.

Humidity (Non-Operating)

5% to 95% relative humidity (non-condensing) as tested per MIL–PRF–28800F.

Altitude (Operating)

up to 3048 m (10,000 ft) at up to 25 °C

Altitude (Non-Operating)

up to 12,190 m (40,000 ft)

Vibration (Operating)

Random vibration, 0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes

Vibration (Non-Operating)

Random vibration, 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes

Functional Shock

20 gpeak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total

Certification

UL (Std. UL 61010-1 2nd Edition) & cUL (Std. CSA C22.2 No. 61010-1-04) Listed. CE Compliant. EMC Directive 89/336/EEC; EN 61326:1997/A3:2003. Low Voltage Directive 73/23/EEC; EN 61010-1:2001.

Physical Dimensions

Dimensions (HxWxD)

260 mm x 340 mm x 154 mm (10.25" x 13.4" x 6") excluding accessories and projections.

Net Weight

6.95 kg (15.5 lbs.) excluding accessories.

General

Power (AC)

90–264 Vac, 47–63 Hz (90–132 Vac, 380–420 Hz); Max. Power Consumption: 300 VA

Power (DC)

Not Available

Warranty and Calibration

Three year warranty. Calibration recommended yearly.